Chapter-6 |Transducer

We know that the generalized measuring system consists of three functional elements(the transducer is the first stage):

  1. primary detector-transducer stage,
  2. intermediate modifying stage, and
  3. the output or terminating stage.

 Each stage performs certain functions so that the value of the physical variable to be measured (measurand) is displayed as output

pressure transducer

What is Transducer?

A transducer is a device that converts one form of energy into another form.

 The transducer, which may be electrical, mechanical, optical, magnetic, piezoelectric, etc., converts the sensed information into a more convenient form.

The detecting or sensing element of a measuring system first makes contact with the quantity to be measured, and the sensed information is immediately transduced into an analogous form.

signal process of the transducer
By Brews ohare – Own work;… Uses File:EAR.jpg and File:Sexy-Red-Lips Happy-Girl.jpg, CC BY-SA 3.0, https://commons.wikimedia.org/w/index.php?curid=19048816

Classification of Transducers

Analog and Digital Transducers

 In the case of analog transducers, the input quantity is converted into an analog output, which is a continuous function of time.

LVDT, strain gauge, thermocouple, and thermistor are some examples of analog transducers.

 If a transducer converts the input quantity into an electrical signal that is in the form of pulses, as output, it is called a digital transducer.

These pulses are not continuous functions of time but are discrete in nature. Examples are shaft encoders, linear displacement transducers.

Terminating Devices

Meter Indicators

Meter indicators can be categorized as follows:

  1. Simple D’Arsonval type to measure current or voltage
  2. Volt–Ohm milliammeters or multimeters
  3. Vacuum tube voltmeters

Simple D’ArsonvalType to Measure Current or Voltage

 It essentially consists of components like a permanent

magnet, coil, hairsprings, pointer, and scale. The coil assembly is mounted on a shaft, which in turn is hinged on a hairspring.

 To concentrate the magnetic fields, initially, the iron core is placed inside the coil.

 The curved pole pieces are then attached to the magnet to ascertain if the torque increases as the current increases.

This means that electromagnetic energy is used to move the meter.

Volt-Ohm Milliammetersor Multimeters 

The typical volt–ohm milliammeter employs switching provisions for connecting multipliers, shunt resistors, and rectifier circuits.

The current flowing through the resistor can easily be determined by switching over to the ohm-meter function, wherein the leads can be connected to the unknown resistance that causes the meter movement.

The advantage is that direct measurement is possible since the current flow indication is calibrated in terms of resistance

Vacuum Tube Voltmeters

The vacuum tube voltmeter, popularly known as VTVM, is basically used to measure voltage.

To control the grid of the tube, proper multiplier resistors are employed through which the AC or DC input is given to the meter.

The input resistance of a VTVM is usually very high when compared to that of a simple meter, due to high grid circuit resistance. This minimizes the loading of the signal source.

Cathode Ray Oscilloscope

  CRO is a voltage-sensitive device that is used to view, measure, and analyze waveforms.

Its advantage is that a beam of electrons with low inertia strikes the fluorescent screen, generating an image that can rapidly change with varying voltage inputs to the system.

 The cathode ray tube (CRT) is the basic functional unit of CRO. The electron gun assembly comprises a heater, a cathode, a control grid, and accelerating anodes. When a cathode is heated, electrons are generated.

The accelerating anodes, which are positively charged, provide the necessary striking velocity to the emitted electron stream.

The electron beam, after gaining necessary acceleration, passes through horizontal and vertical deflection plates, which provide the basic movements in the X and Y directions.

XY Plotters

The XY plotters generate Cartesian graphs, which are obtained by two DC inputs, in X, and in the Y-axis. It consists of two self-balancing potentiometers, one to control the position of the paper and others to control the position of the pen.

 In XY plotters, the output is generated by plotting one emf as a function of the other emf.

 Further, the emf, which is the output signal of transducers, may be a value of displacement, force, pressure, strain, or any other parameter.

Next, Chapter-7 | Temperature Measurement

Back to Home Page

Preview, Chapter-6 |Transducer

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google photo

You are commenting using your Google account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s

%d bloggers like this: